Search Documents

Search Again

Search Again

Refine Search

Publication Date
Clear

Refine Search

Publication Date
Clear
Organization
Organization
  • DFI
    Compaction-Induced Lateral Earth Pressures And Vertical Shear Forces Acting On Non-Moving Retaining Walls

    By George M. Filz

    Restrained basement walls and unrestrained but massive concrete walls on rock foundations experience very small movements in response to lateral earth pressures. Such walls are often designed using at

    Jan 1, 2003

  • DFI
    Session 14 "Deep Mixing Method III"

    By Stefan Dahlin

    The laboratory tests indicated low permeability but as I said, as a rule, the permeability in the field has been found to be higher. A high permeability has also been found when doing back calculation

    Feb 10, 2003

  • DFI
    Session 11 Jet Grouting II

    By George Burke

    Of the three projects, particularly the extensive Nimitz II (downtown) project, a single system, which was part of the operation, was used to control the spoil. Spoil control was continuous with the w

    Feb 10, 2003

  • DFI
    Suwanee American Cement Plant, Branford, Florida: A Case Study Of Large Diameter Continuous Flight Auger Design Build Foundations

    By Gordon King

    This paper presents a case study of large diameter continuous flight auger (CFA) piles and drilled shafts utilized for foundation support of a series of heavily loaded cement plant structures at the S

    Jan 1, 2003

  • DFI
    Depth Of Borings, Length Of Piles, Landslides, Erosion, And A Moose Hunt - A Case History Of A Comedy Of Mistakes

    By Bengt H. Fellenius

    An upgrading and straightening of a highway included building a bridge across a small river. A routine site investigation was initiated to determine the conditions for designing the foundation of the

    Jan 1, 1987

  • DFI
    A Case Study In Hand-Dug Caissons ? Synopsis

    Caissons hand dug to a depth of about 100 feet were used to underpin three important structures at an industrial site in the State of Utah. The caisson shafts extended through 30 to 40 feet of coarse,

    Jan 1, 2010

  • DFI
    Parametric Analysis Of Piled Rafts Founded On A Tropical Clay Of Brazil

    By Renato P. Cunha

    The paper presents the results of a comparative and parametric analysis in which a numerical program developed exclusively for groups of deep foundations under general loading (vertical, horizontal an

    Jan 1, 2002

  • DFI
    Methods Of Dewatering And Ground Water Control ? Synopsis

    By J. P. Powers

    Methods for dewatering and the control of ground water for construction and mining are discussed, including open pumping; predrainage with deep wells, wellpoints or other systems; cutoff or exclusion

    Jan 1, 2010

  • DFI
    Construction Of Deep Foundations By Cast-In - Borehole Method

    By Y. W. Mou

    In order to improve the construction of pile foundations and deep foundations of largo sizes, the paper deals with the method of installing square or rectangular bored-piles for annular foundation as

    Jan 1, 2010

  • DFI
    Pile Foundations In Liquefiable Soils - A Case Study - Synopsis

    By R. K. M. Bhandari

    Geotechnical investigation for a LPG plant located in Assam state - an area of high seisimicty - revealed a layer of loose to medium silty sand susceptible to liquefaction at some depth below the fini

    Jan 1, 1996

  • DFI
    Construction Of Large Open Caissons In Soft Stratum

    By Chen Zhiquan

    Author has exhaustively researched into soft ground through construction of a large open caisson on soft ground (muck) which weighs more than 4, 000 tons. To avoid any contingency during construction,

    Jan 1, 1991

  • DFI
    Full Scale Loading Tests Of NF Pile ? Synopsis

    By M. Nomura

    This paper describes the results and field measurements of two long-term observation tests and two short-term loading tests to confirm the effectiveness of NF piles in reducing negative skin friction.

    Jan 1, 2010

  • DFI
    A Study Of Failure Mechanism And Uplifting Capacity Of Tension Pile Foundation ? Synopsis

    By K. J. Yang

    Based on investigations and model tests combined with pile foundation on Code compilation of drydocks, we present this report to give informations against uplift pressure of piles beneath floor of dry

    Jan 1, 2010

  • DFI
    Behaviour Of Laterally-Loaded Piles Centrifugal And Numerical Modelling ? Synopsis

    By W. H. Craig

    Techniques have been developed for installing model piles into beds of soil under high sustained acceleration levels aboard a centrifuge. These piles have been subjected to static and/or cyclic latera

    Jan 1, 2010

  • DFI
    Ground Improvement Resulting From Installation Of Drilled Displacement Piles

    By Timothy C. Siegel

    Drilled displacement piles (also known as augered cast-in-place displacement piles or augured, pressure grouted displacement piles) are installed by the displacement of soil and subsequent placement o

    Jan 1, 2007

  • DFI
    Studies On Pile Driving Cushion Materials ? Synopsis

    By H. R. Shen

    Cushion materials are one of the most important links in an efficient piling system. In the past, little has been done in China on this problem, so engineers are still used to those traditional woods,

    Jan 1, 2010

  • DFI
    Self-Drilling Micropiles

    By Matt Sotirin

    The Santa Fe train station and passenger rail platform were constructed in the downtown district of Fort Madison, Iowa, over a century ago. This landmark building and rail platform were in need of maj

    Oct 1, 2022

  • DFI
    Static Behavior Of Single Piles Subjected To Repeated And Reciprocating Loadings ? Synopsis

    By L. Z. Xie

    The results of the experimental study on the static behavior of single piles subjected to repeated and reciprocating axial loadings are recommended in this paper. Tests of four full-scale single piles

    Jan 1, 2010

  • DFI
    Underpinning A Deep Foundation ? A Case History ? Synopsis

    By M. Soranzo

    This paper presents a restoration operation of the load-bearing capacities of a deep foundation which did not satisfy the original design conditions. The operation was preceded by a series of tests ca

    Jan 1, 2010

  • DFI
    Cost Analysis Of Multiline Ring Anchor Systems For Offshore Wind Farm

    By Junho Lee, Leopoldo Bello, Mohammad Khan

    Multiline ring anchor (MRA) was developed as a cost-effective solution for securing floating offshore wind turbines (FOWTs) to the seabed. Since FOWTs are placed in arrays compared to conventional oil