Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Design Of Laterally Loaded Single Pile In Sand Near Slope - A Proposal For Subgrade Reaction FactorsBy Salim Mezazigh
Usually different methods for designing a single pile submitted to a lateral loading are available. They are based on theory of elasticity with the parameters E,v or subgrade reaction method using the
Jan 1, 2002
-
PSC Piles Overcome Challenges for $650m Power PlantBy Tim Siegel, III Fondren, Billy Camp
"INTRODUCTIONThe new $650 million power block at Santee Cooper’s Cross Generating Station in Cross, South Carolina is being constructed on driven pre-stressed concrete (PSC) piles. S&ME, as geotechnic
Jan 1, 2004
-
Vertical Bearing Capacity of Pile Installed by "EX MEGATOP" Method - Base Enlarged Pre-boring and Grouting Method for Pre-cast PileBy Hitoshi Ogura, Koichi Kobayashi, Sadao Yabuuchi
"In Japan, most pile foundations using pre-cast concrete piles are installed by the bored pre-cast piling method, wherein pre-cast piles are installed in holes that have been excavated beforehand and
Jan 1, 2005
-
Pile Construction And Related Problems ? SynopsisBy K. Fujita
In order to deal properly with the fundamental aspects of pile construction, the following problems and their solutions are introduced: For driven piles - stresses, damage, movements of surroundings,
Jan 1, 2010
-
Piled Rafts In Geotechnical Practice - An International PerspectiveBy Michael W. Neill, O&apos
The performance of foundations that combine the high bearing capacity of rafts (mats) with the settlement reduction capability of piles is described through a summary of 24 case histories. Structures
Jan 1, 2003
-
Dynamic Characterization Of Drilled Shafts On Doremus Avenue BridgeBy Martina Balic
Dynamic properties of the drilled shaft foundations supporting Doremus Avenue Bridge were determined by forced vibration testing. The main objectives of the substructure testing at Doremus Avenue Brid
Jan 1, 2004
-
Osterberg Cell Tests Confirm In-Situ Pier Capacity In Colorado - IntroductionBy William Siegel
Kleinfelder provided foundation analysis and design for an expansion to a cement plant in Florence, Colorado. The expansion was a conversion from a horizontal wet process to a vertical dry process, a
Jan 1, 2007
-
Keynote Lecture 3: G. Stuart Littlejohn Compensation and Permeation GroutingBy G. Stuart Littlejohn
In spite of recent concerns in certain European countries, I believe that silicate-ester grouts will continue to be employed in practice, unless more cost-effective inorganic grouts are developed for
Feb 10, 2003
-
Large Diameter Pile Driving, Acceptance And Soil-Pile Setup New East Span San Francisco-Oakland Bay BridgeBy Saba Mohan
This study presents results based on the Pile Installation Demonstration Project (PIDP) that was conducted as a part of the East Span San Francisco-Oakland Bay Bridge Seismic Safety Project. For the t
Jan 1, 2002
-
Jobsite Safety Inspection ChecklistBy Sam Messina
[Project: Job Number: Date: Superintendent: Person Making Inspection: Note: The following checklist shall be used on a regular basis as an overall assessment of the jobsite. The checklist
Jan 1, 1998
-
Interpretation Of Full Scale Horizontal Pile Loading Tests In Sand Analysis Of P-Y CurvesBy Ali Bouafia
Five full-scale horizontal loading tests of piles carried out by the LCPC in France are interpreted in order to analyse P-Y load-transfer curves. The experimental piles are either bored or jacked into
Jan 1, 2002
-
Session 15 "Jet Grouting IV"By Mitsuhiro Shibazki
I can't answer that question but I am looking at Andy, my co-author, and he says we didn't measure it. No movement. If I understand it correctly, how do we handle lateral forces in shear? T
Feb 10, 2003
-
Challenges And Recommendations For Quality Assurance Of Deep FoundationsBy Frank Rausche
Although Quality Control (QC) during construction is preferable for deep foundations, there are many instances when it is necessary to resort to Quality Assurance (QA) methods if, for various reasons,
Jan 1, 2008
-
Estimating Axial Displacements Of Driven Piles In California SoilsBy Cem Akgüner
The displacements of axially loaded single piles are analyzed with an approach based on elasticity. Young?s modulus and Poisson?s ratio of the soil encompassing a pile are the unknowns required as in
Jan 1, 2008
-
Vertical Load Carrying Capacity Of Concrete Expanded Base PilesBy Mustapha Zergoun
This paper presents the results of load tests to assess the vertical load carrying capacity of concrete expanded base piles, or pressure injected footings, for various projects located near Vancouver,
Jan 1, 2004
-
Pile Driving Hammers In Centrifuge Modelling - SynopsisBy Daniel Levacher
Pile load tests in site require extensive means of action and time. To get outstanding tests, the environmental test conditions must be perfectly known and acceptable. They concern the support install
Jan 1, 1996
-
Stone Columns At Trenton Water Treatment Facility - Suitable Alternative To Remove And Replace For Mat FoundationBy Darrell Wilder
The Trenton Water Treatment Facility in Trenton, New Jersey, is expanding to upgrade existing facilities and to meet the increasing demands of the public. The facility sits uncomfortably between the
Jan 1, 2008
-
Reliability Approach For Deep Foundation Studies ? SynopsisBy R. Chowdhury
The relevance of reliability studies for deep foundations is considered in this paper with special reference to pile foundations. Attention is drawn to uncertainties related to applied loads, the load
Jan 1, 2010
-
A Proposed Model For Soil/Auger Interaction During Installation Of Screw Piling Augers - SynopsisBy J. W. Slatter
Cast in situ screw piling techniques (both displacement and non displacement) have seen considerable growth in recent years due to competitive production rates, low noise and vibration free installati
Jan 1, 2000
-
Improvements In Deep Compaction Using Vibratory Pile HammersBy Dennis Nottingham
Increased interest in seismic soil liquefaction and preventative soil stabilization sets the stage for improved deep compaction methods using pile driving techniques. In 1971 L.B. Foster Company perso
Jan 1, 2004