Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
Installation Checklist For Driving Mega PilesBy Douglas L. Scaggs
Over the past several years, pile foundations have grown to meet the demands of larger and heavier structures. As the foundations have grown, so has the need for larger and more robust piles to carry
Jan 1, 2013
-
Design And Construction Of The Rion Antirion Bridge FoundationsBy Alain Pecker
The choice of a design concept for a bridge foundation is guided by various factors; several of these factors are indeed of technical origin, like the environmental conditions in a broad sense, but ot
Jan 1, 2013
-
Finite Element Analyses And Cofferdam ExcavationsBy Dimitrios C. Konstantakos
Cofferdam excavations have traditionally been designed with classical design methods that involve direct computations of active or apparent earth pressures. However in contrast to finite element metho
Jan 1, 2013
-
The Construction And Performance Of Post-Grouted Micro-Piles For Vancouver International Airport Domestic Terminal Building - IntroductionBy Ernest Naesgaard
Post-grouted micro-piles were used for the seismic upgrading of the Vancouver International Airport Domestic Terminal Building (DTB). The micro-piles provided vertical resistance to both uplift and c
Jan 1, 2004
-
Ground Improvement Utilizing Vibro Probes Eliminates Liquefaction Concern For A Bridge FoundationBy Aly M. Mohammad
Croton Point Avenue Bridge carries Croton Avenue over Metro-North main tracks at Harmon Rail Yard in Westchester County, New York. The new bridge is 1100 foot long and 36 foot wide nine span structur
Jan 1, 2007
-
JFKIA - Post Grouted Drilled Shafts And Driven Piles - Update - SynopsisBy Walter G. Brusey
This paper describes a comprehensive pile test program conducted at John F. Kennedy International Airport (JFKIA) to evaluate pile types and design capacities ranging from 890 to 4450 KN (100 to 500 t
Jan 1, 2000
-
Underpinning System Based On Preloaded Micropiling For Construction Of Additional Underground FloorsBy Wolfram Groh
New underground floors comprising the complete footprint area of the building structure, were constructed under an existing building in sand, located in the Verdun district of Beirut / Lebanon. The wo
Jan 1, 2002
-
Ultimate Lateral Load of a Pile in Cohesive Soil under Static LoadingBy Dileej M. Dewaikar, Poonam A. Patil
"In this paper, the ultimate lateral resistance of a long, flexible, unrestrained vertical pile in a cohesive soil is computed under static loading condition using py curves. A simple and improved met
Jan 1, 2005
-
Redwood Tower; A Landmark In Deep Foundation Construction ? SynopsisBy A. Partos
It was decided to build a fourteen-storied office building over a six-storied garage and a four-storied office building. The high vertical and horizontal loads required foundations on rock approximate
Jan 1, 2010
-
Session 22 "Compaction Grouting and Limited Mobility Grouting"By Allen Cadden
The type of soil we had was a silty fine sand. It had been placed by hydraulic methods in 1904 so it was quite clean I would say less than 10% silt the rest of it was very loose sand. That I'm n
Feb 10, 2003
-
Underwater Sound Attenuation In Construction Projects: Applying Science To Pile Driving PermitsBy Alan Christopherson
Nearshore construction projects often require installation of steel piles and specific methodologies of installing piles may adversely affect nearby species of concern. Water is an uncompressible med
Jan 1, 2013
-
Load Tests Of Bored Piles In Weathered BedrockBy James C. Scott
Compression and tension load testing were performed on bored concrete piles installed to depths of 18 to 34 meters below excavation levels for a large mixed-use development in Kuala Lumpur, Malaysia.
Jan 1, 2007
-
Underpinning And Micropiling To A Four Storey Apartment Building In Hamilton, ScotlandBy Clifford J. Wren
A geotechnical foundation solution was required to halt and prevent further structural distress suffered by a residential four storey apartment building in Hamilton, Scotland. Residents of the ten ye
Jan 1, 2008
-
Diameter Effects On p-y CurvesBy Ignatius P. O. Lam
This paper presents information on design analyses of large diameter piles using conventional p-y curves as recommended by the American Petroleum Institute (API RP2A, 1993). API RP2A adopted the soft
Jan 1, 2013
-
Permanent Soil Nail Earth Retention System, Stanley Hall Replacement Project, UC BerkeleyBy Pirooz Barar
The new Stanley Hall building will house the center for bio-engineering and technology research for the UC Berkeley campus. The structure is located at the northeast part of campus, adjacent to Donne
Jan 1, 2004
-
Time-Dependent Increase In Load Capacity Of Tapered PilesBy Jeongbok Seo
This paper describes successful application of driven tapered-steel-pipe piles for two large-scale projects in the New York metropolitan area: Rego Park Mall, Rego Park, N.Y. and 164 Kent Avenue, Broo
Jan 1, 2008
-
Design And Construction Of The Sutong Bridge FoundationsBy Robert B. Bittner
The Sutong Bridge across the lower Yangtze River in China will have, when completed, the longest span (1,088 m) and the highest towers (306 m) of any cable stayed span in the world. The foundations f
Jan 1, 2013
-
The Resonant Driver: Ultra High Frequency Pile And Casing InstallationBy Matthew Janes
The installation of piles and casings is becoming increasingly difficult as restrictions on vibration become common in major urban areas. The use of high frequency, resonant excitation of a pile or c
Jan 1, 2008
-
Assessing the Applicability of Thermal Response Testing to Energy PilesBy C. Guney Olgun, Fleur Loveridge, Tracy Brettmann, William Powrie
"Abstract Deep foundations are increasingly being used, not just to carry structural loads, but also to act as heat exchangers as part of a ground source heat pump system. Such foundations, often call
Jan 1, 2014
-
Dynamic Centrifuge Model Tests on Pile-Type Deep Mixing Method Reducing Lateral Flow of Liquefied GroundBy Tsuda Wakaki, Naoki Takahashi, Natsuki Okuno, Hidenori Takahashi, Ikuo Towhata, Yoshiyuki Morikawa
"Deep mixing (DM) method has been increasingly employed as a countermeasure against subsoil liquefaction in recent years. Pile-type DM, however, is considered to have little effect as a liquefaction c
Jan 1, 2015