    Bentonite Self-Hardening Slurry Mix Variations and Field Implementation Methods

    By Christopher R. Harris

    "Considerations are presented for developing and implementing self-hardening slurry mix designs to be utilized in barrier seepage walls. Slag-cement-cement-bentonite (SCCB) slurries are the primary fo

    Jan 1, 2016

  • DFI
    Effective Sampling, Testing and Specification Approaches for Deep Mixing at Kitimat LNG, BC

    By Randy R. Williams, Brian W. Wilson, George M. Filz, Marina S. W. Li, Donald A. Bruce

    "In-situ wet grab sampling and post-installation coring of soil-cement structures are typically carried out for Quality Control (QC) and Quality Assurance (QA) of deep mixing (DM) schemes. Wet grab sa

    Jan 1, 2015

  • DFI
    Design Of Ground Improvement By Inclined Dsm Columns For Railway Embankment (Türkiye)

    By Emre Turk, Suat Gullu, Candan Gokceoglu, Ahmet Sirri, Asli Can

    In this study, the ground improvement application applied under the live railway bridge's approach embankments in Sivas, Türkiye was investigated as a case study. The soil profile is mainly composed o

    Oct 1, 2022

  • DFI
    Strength and Deformations of Piles Supporting Transient Pipe Anchors in Heavy Industrial Pipelines

    By Konstantin G. Ashkinadze

    The paper considers performance of piles supporting transient pipe anchors in heavy industrial pipelines. Events such as pump trips or opening and closing of large valves produce short-term dynamic pu

    Jan 1, 2016

  • DFI
    Drilling and Grouting For the Rehabilitation of Contaminated Areas: An Italian Case History

    By Raffaella Granata, Daniele Vanni

    "This paper presents the drilling and grouting program performed at two abandoned landfills located into former calcarenite rock quarries in Manfredonia, Italy. Tests performed after the abandonment o

    Jan 1, 2016

  • DFI
    Influence of Surface Replacement Layer on Behavior of Laterally Loaded Large Bored Piles in Soft Clay: Pile Load Tests and Numerical Investigation

    By Hayel M. El-Naggar, Mohamed Sobhi, Mamdouh M. Hamza, Marawan M. Shahien

    "This paper presents the results of two lateral load tests on large bored piles in soft clay deposit for a major site in northern Egypt. The tests are carried out on 0.8 m diameter piles. One of the t

    Jan 1, 2016

  • DFI
    Alternative Design and Construction Method for Clinton CSO Underground Storage Facility

    By Meeok Kim, Paul Beljan, Gordon Chen

    "Clinton combined sewer overflow storage (CSO) facility project developed by the Department of Water Environment Protection of Onondaga County, New York, is to improve sewer facilities and infrastruct

    Jan 1, 2015

  • DFI
    Optimizing Large Diameter Concrete Piles in Tidewater Virginia

    By Michael G. Batten, Brian D. Keaney

    ]The Virginia Department of Transportation (VDOT) and the harbors on the James River routinely use precast concrete piles founded in the Yorktown formation to support bridges and other coastal structu

    Sep 8, 2021

  • DFI
    Ideas To Improve Driven Pile Foundation Design And Installation Procedures

    By Armin W. Stuedlein, Steven R. Saye

    The differences between calculated axial pile capacity and the capacity realized during and following installation has long presented a significant concern for foundation engineers and contractors. Su

  • DFI
    Simplified Model for Increased Lateral Resistance of Deep Foundations Using Soil Mixing

    By Hubert Law, Dan A. Brown, Kyle M. Rollins

    "Soil mixing and jet grouting provide a means to significantly increase the lateral resistance of pile group foundations with relatively little investment of time, effort, and expense compared to the

    Jan 1, 2015

  • DFI
    Deep Foundation Advancements in Fargo

    By Ezra Ballinger, Matthew R. Glisson

    Located in downtown Fargo, North Dakota, the Block 9 Redevelopment project site contains highly- compressible soils in the upper 100 feet with groundwater about 10 to 15 feet below the existing ground

    Jan 1, 2019

  • DFI
    Case Study on the Frederick Douglass Memorial Bridge and the use of Large Diameter Open End Steel Pipe Piles, Washington, DC

    By Karl A. Higgins, Michael D. Venezia

    The South Capitol Street Corridor Project is one of the District Department of Transportation’s (DDOT) largest projects, and is currently under construction. This case study will focus on the design o

    Jan 1, 2019

  • DFI
    The Development and State of Practice of Cutter Soil Mixing in North America – The First 10 Years

    By Brian Wilson, Franz-Werner Gerressen

    "Cutter Soil Mixing, also known as CSM, was developed in Europe as an alternate method of Deep Mixing to the more traditional single and multiple auger techniques, and brought to market by Bauer Masch

    Jan 1, 2015

  • DFI
    Correlation between Undrained Shear Strength in Dry Deep Mixing Columns and Unimproved Soft Soil

    By Stefan Larsson, Jan Ekström, Jennie Kock-Larsen, Håkan Garin

    "This paper describes the testing procedure (or protocols) for quality control of dry deep mixing columns in a major ground improvement project carried out in Sweden. Quality control was mainly based

    Jan 1, 2015

  • DFI
    Versatility of Compaction Grouting to Stabilize and Lift Large Structures

    By Joe Harris

    Large structures, such as a multistory office building or a large storage tank, are constructed the most economical way possible, which may involve a shallow foundation system placed on native soil or

    Sep 1, 2023

  • DFI
    Construction Methods and Quality Outcomes for Bored Cast-in-Situ Piles – A Review of Current Practice

    By Jim Slatter, Ben Collingwood

    "It is well known that the adoption of an appropriate construction methodology is critical to quality outcomes for bored piles (drilled shafts). Many case studies have been published documenting quali

    Jan 1, 1900

  • DFI
    Acceptance Of Timber Piles Based On Equivalent Driving Energy

    By Chu E. Ho

    This paper describes a case history involving the use of the Equivalent Driving Energy concept for evaluating timber piles that failed to achieve the termination criterion traditionally based on final

  • DFI
    Unified Design Of Piles And Pile Groups Considering Capacity, Settlement, And Negative Skin Friction - 1. Introduction

    By Bengt H. Fellenius

    It is a truism that in the design of pile foundations one must consider both capacity and settlement. As to capacity, most basic text books contain simple methods of design of capacity of single pile.

    Jan 1, 1991

  • DFI
    ACIP Pile Performance and Installation in the Northeastern United States

    By Jr NeSmith

    "Augered-cast-in-place (ACIP) pile installation technology has matured extensively since the first auger, pressure grouted pile was patented in 1959. The current technology allows for successful pile

    Jan 1, 2016

  • DFI
    Installation Of Three Up To 120M Deep Diaphragm Wall Shafts, With Diameters Between 8M And 35M At Woodsmith Mine In North Yorkshire (England)

    By Gustav Jahner, Michael Baltrusch, Norbert Hoffmann

    Near the port city of Whitby in the north-east of England, Anglo American (AA) is setting up the deepest mine in the UK, which will have a depth of 1,500m. The purpose of the project is to extract and

    Sep 1, 2022