Behavior Of Step Tapered Bored Piles In Sand Under Axial LoadingBy Nabil F. Ismael
The axial capacity of step tapered bored piles in sand was examined by field tests at one site in Kuwait. Two straight piles, and two step tapered piles were load tested in compression to failure. Al
Jan 1, 2008
-
Soil Nail Support Of Excavation System For The Embassy Of The Peoples Republic Of China In The United StatesBy Giovanni A. Bonita
The new Embassy of the Peoples Republic of China in the United States (Chinese Embassy) is located in the Embassy Row portion of Northwest Washington DC. The 475,000 ft2 (44,125 m2) struct
Jan 1, 2006
-
The Seven Steps To Foundation RetrofitBy Javier Rodriguez
Adaptive re-use of existing structures in urban environments has become very common due to lack of available space in our cities and requirements for increased structural capacity. Often, it involves
Jan 1, 2006
-
The "DSEI" Joint: A Destructible Diaphragm Wall Joint (Patented Process)By Christian Besson
This article describes the implementation of a new jointing process for use between diaphragm wall panels. This process was initially introduced on the SOCATOP work site in uburban Paris (which involv
Jan 1, 2002
-
Economic Foundation Design For Tall BuildingsBy Frances Badelow
This paper describes a design process for piled raft foundations supporting high-rise buildings. The design process comprises an initial stage of geotechnical site characterization using the results o
Jan 1, 2006
-
Size And Loading Rate Effects Observed In Plate Load Tests On A FillBy Kazuyuki Matsuzawa
A series of plate loading tests were carried out on a loam ground in order to investigate the influences of the plate size and the loading rate on the observed load-settlement relations. Two circular
Jan 1, 2006
-
Double Rotary CFA Piles: Performance In Cohesive SoilsBy Michel Bustamante
The occasional substandard performances of continuous flight auger in particular soil conditions have prompted the drilling rig manufacturer to improve the standard CFA in order to reduce its negative
Jan 1, 2002
-
Advances In Seismic Design Considering Soil- Structure InteractionBy Y. C. Han
The advances in seismic design considering soil-structure interaction or soil-pile-structure interaction are described using a substructure approach. The nonlinearity of soil is considered approximate
Jan 1, 2010
-
Settelement Of A Piled-Raft Foundation Considering Lateral Pile ResistanceBy Helen S. W. Chow
The use of piled raft foundations for tall buildings has been increasing in this decade as it is an economical alternative to conventional piled foundations. Piled rafts are composite structures compr
Jan 1, 2006
-
Concrete Overbreak Estimation and Analysis Errors in Bored PilesBy Nuno Cruz
"The concrete overbreak estimation for bored piles provides the quantification of the shaft’s expansion beyond its theoretical volume. There are stability analysis methods that can be employed before
Jan 1, 2017
-
Static Uplift and Lateral Load Testing of Piles for a New Power PlantBy José L. M. Clemente, John R. Davie
"Abstract An extensive pre-production static and dynamic pile load testing program was conducted for a coal-fired power plant. The static load testing program included axial compression, uplift (tensi
Jan 1, 2014
-
Vertically Loaded Piles In Sand Subjected To Triangular Profiles Of Soil MovementsBy W. D. Guo
With an experimental apparatus developed recently, model tests on piles were conducted in sand subjected to triangular soil movement profiles. Four instrumented piles tests are reported, which show th
Jan 1, 2006
-
Effect Of Vertical Heterogeneity In Soil Strength On Pile Bearing Capacity Prediction From CPT DataBy Amaneh E. Kenarsari
Among the different sources of uncertainty in pile bearing capacity prediction including inherent heterogeneity, measurement and model uncertainties, the inherent heterogeneity of soil properties is o
Jan 1, 2011
-
Nonlinear Response of Piles with Rigid Embedment: Lessons Learned from a Reduced- Scale ExperimentBy Camilla Favaretti, Benjamin Turner, Anne Lemnitzer
Pile foundations are extensively used in the construction of various types of superstructures, including tall buildings, bridges, freeways and offshore structures. A fully constrained tip embedment su
Jan 1, 2018
-
Reliability Of Pile Prediction Methods - SummaryBy M. T. Davisson
Pile compression load capacity prediction methods are divided into four categories for purposes of discussing their reliability compared to static load test results. The categories considered are: 1)
Jan 1, 1991
-
Predicting The End Bearing Capacity Of Rock Socketed ShaftsBy Lianyang Zhang
For optimal design of rock socketed shafts used to support axial loading, it is important to predict the end bearing capacity. The existing empirical methods for determining the end bearing capacity o
Jan 1, 2008
-
Design Of Drilled Pier In Expansive SoilsBy G. T. Hong
A numerical model for use in design is developed to predict the stresses and axial and bending displacements in a drilled pier in expansive soils. The prediction is based on the horizontal swelling p
Jan 1, 2007
-
Hyperbolic P-Y Model For Static And Cyclic Lateral Loading Derived From Full-Scale Lateral Load Testing In Cemented Loess SoilsBy Steven Dapp
A new hyperbolic model for generating P-Y curves is developed for use in lateral analyses of cemented soils (a ?C-F? soil with both cohesive intercept and friction angle), and includes degradation of
Jan 1, 2011
-
Axial Cyclic Degradation of Marine Piles: A Strain-Based Fatigue LimitBy Aaron S. Bradshaw, Ryan M. Coulson
The offshore wind industry in the United States is slowly emerging with the recent construction of the first offshore wind farm located off the coast of Rhode Island. The turbines at the Block Island
Jan 1, 2018
-
Experimental Evidences From A Pile Load Test On A Driven Composite PileBy A. Garassino
A pile design was performed for a thermal power station in Egypt and more than 4000 piles were to be driven. Technical economical reasons suggested the choice of driven composite LACOR piles designe