Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Redwood Tower; A Landmark In Deep Foundation Construction ? SynopsisBy A. Partos
It was decided to build a fourteen-storied office building over a six-storied garage and a four-storied office building. The high vertical and horizontal loads required foundations on rock approximate
Jan 1, 2010
-
Analyses Of Dynamic Increasing Energy Load Test On Deep FoundationsBy Silvana B. Foá
Results from full-scale loading tests showed the use of the dynamic increasing energy test (DIET) to verify the capacity of deep foundations. This method allows the measurement of dynamic resistance -
Jan 1, 2002
-
Experiences From A Large Scale Driven Precast Piling Project In IndiaBy Rajesh A. Vaidya
A large scale piling work is undertaken in India for an important fast track industrial project. Thousands of solid square precast concrete piles are driven to depths of around 50m. Soils encountere
Jan 1, 2007
-
Session 10 Deep Mixing Method IBy Peter Cali
There is one organization in Sweden, The Swedish Deep Stabilization Research Centre, which has been working with these questions and there is also a project, Eurosoilstab, within European Union to tak
Feb 10, 2003
-
A General Formula To Determine The Allowable Pile Bearing Capacity In Case Of Negative Skin Friction ? SummaryBy Cornelis Van Der Veen
Foundation piles, partly passing through unconsolidated compressible layers, suffer a downward drag that is called negative skin friction. The negative skin friction depends on the movement of the sur
Jan 1, 2010
-
Construction Of Deep Foundations By Cast-In - Borehole MethodBy Y. W. Mou
In order to improve the construction of pile foundations and deep foundations of largo sizes, the paper deals with the method of installing square or rectangular bored-piles for annular foundation as
Jan 1, 2010
-
Optimization Of Pile Length Using Decision Analysis With Information From Load Tests During ConstructionBy Jiun-Yih Chen
Pile load tests are regularly used to verify pile capacities. Sometimes, they are used to optimize pile designs. This paper presents a case study based on a real project, in which the information ob
Jan 1, 2009
-
Ground Energy Systems In London - A Best Practice ApproachBy Ryan Law
Ground energy systems are being installed in increasing numbers in the United Kingdom. This is particularly true in London where planning regulations require larger scale developments to provide at l
Jan 1, 2008
-
Research On The Interaction Between Pile And Foundation Soil By Boundary Element MethodBy Wang Lushuang
This thesis is devoted to the research of the interaction between pile and foundation soil by boundary element method (BEM for short). The interaction is simulated by the interaction between two diffe
Jan 1, 1991
-
Session 14 "Deep Mixing Method III"By Stefan Dahlin
The laboratory tests indicated low permeability but as I said, as a rule, the permeability in the field has been found to be higher. A high permeability has also been found when doing back calculation
Feb 10, 2003
-
Foundation Performance of Millennium Tower in San Francisco, CaliforniaBy John A. Egan, Nathaniel Wagner, Micaela Largent, Jonathan P. Stewart, Debra Murphy, Jeremy Butkovich
The Millennium Tower is a 58-story reinforced concrete building that was constructed in San Francisco, California between 2005 and 2009. The Tower is founded on an embedded pile supported mat with pil
Sep 8, 2021
-
Deep Soil Mixing Use in PolandBy Michal Topolnicki
Deep Mixing Series: This article is the second keynote highlighted from DFI's virtual Deep Mixing Conference in 2021, for which Topolnicki served as a committeee co-chair Polish applications of deep s
Apr 1, 2022
-
I Don't Have X-ray Vision: Risk-Informed Site InvestigationBy Georgette Hlepas
How often phrases like these have been made by project managers and project teams trying to explain why there has been cost growth, project delays and differing site conditions claims. But does it re
May 1, 2022
-
Installing And Testing Multi-bar High Capacity Rock TiedownsBy Andrew Pontecorvo, Steven Lowe, David Sposito
Buildings with large height-to-width ratios require foundations with significant uplift resistance. This paper presents a case study of the permanent rock tiedowns installed for One Manhattan West, a
-
Rock Socket Friction In Drilled Shafts - Its Greater Than You Think - Summary.By Jorj O. Osterberg
The practice of using side shear resistance in the design of drilled shafts socketed in rock is discussed. In the absence of field test data for the particular rock involved, the designer often neglec
Jan 1, 1991
-
A Realistic Approach Toward Stray Current Induced Corrosion Affecting Steel Sheet PilingBy Anne Fagot
Because of the risk of corrosion caused by stray currents, steel foundations and steel sheet piling are generally prohibited in the vicinity of railway structures. Steel solutions are only accepted if
Jan 1, 2008
-
Application Of Several Soil Improvement Methods In ChinaBy J. H. Qian
China is one of the countries with comparatively wide distribution of soft soil. In the wake of the rapid developement in the national economy and construction, the improvement technique of soft soil
Jan 1, 2010
-
Behavior Of Pile Foundation Under Impact Lateral LoadsBy Hajialilue Bonab M.
The soil-pile interaction under lateral impact loads is not yet completely well known. Many tests on single piles under static lateral loads in centrifuge have been performed and P-y curves have been
Jan 1, 2002
-
Analysis Of Vibratory Driven Pile ? IntroductionBy Sherrill Gardner
Vibratory drivers have been used since the 1930s to drive and extract piles. Vibratory pile drivers have the capability of significantly decreasing pile installation time, especially in granular type
Jan 1, 1987
-
Centrifuge Modeling Of Axial Failure Of Helical Piles In Cohesive SoilsBy Richard Schmidt, Lijun Deng, Mohamed Abdelaziz, Weidong Li
Helical piles are widely used as a foundation supporting a variety of different structures. Understanding the axial behaviour of helical piles is required to confirm the engineering design. Helical pi