Search Documents
Search Again
Search Again
Refine Search
Refine Search
-
The Development and State of Practice of Cutter Soil Mixing in North America – The First 10 YearsBy Brian Wilson, Franz-Werner Gerressen
"Cutter Soil Mixing, also known as CSM, was developed in Europe as an alternate method of Deep Mixing to the more traditional single and multiple auger techniques, and brought to market by Bauer Masch
Jan 1, 2015
-
Experimental Study on the Bending Failure Properties of Cement-Treated SoilBy Takeru Fukaya, Tsutomu Namikawa
"The bending tensile stress occurs in the ground improvements when external forces are applied to the column and wall shaped ground improvements. Therefore, in the design of the column and wall shaped
Jan 1, 2015
-
Challenges in Managing an Aging Infrastructure, Lessons Learned from a Near Miss at the Lake Manatee DamBy Glen R. Andersen
"Two of the greatest challenges we face in managing our aging infrastructure are to perform accurate condition assessments and to realistically predict the risk of non-action. The aim of this paper is
Jan 1, 2017
-
Mobilisation Of Skin Friction In Bored Piles In Hong Kong ? IntroductionBy R. A. Fraser
Large diameter (1.0 to 2.5m) bored piles have been widely used to support buildings and elevated roadways in Hong Kong. Most of these piles are founded on a hard bearing stratum such as granitic or vo
Jan 1, 2010
-
Reflections on Tremie Concreting in Deep FoundationsBy Gilbert R. Tallard
"Pouring deep foundations by the tremie pipe method is nowadays such a common process that it has becomes an unspecified practice. Means and methods are almost entirely at the contactor’s discretion.
Jan 1, 2017
-
Analysis Of Vertical Piles In Granular Soils Subjected To Static Lateral Loading - SynopsisBy K. Rama Sarma
Piles are frequently subjected to lateral forces and moments in addition to vertical forces and hence the piles have to be designed for both lateral loads as well as vertical loads. In the design of s
Jan 1, 1996
-
Cutoff Wall Selection for Levee ImprovementBy Louay Owaidat
The United States Army Corps of Engineers (USACE) Sacramento District awarded a $64 million construction contract in February 2020 to the Maloney Odin Joint Venture for 3 mi (4.8 km) of levee improvem
Oct 1, 2022
-
Deep Foundation Underpinning Support For Fort Monroe, Virginia YMCA Historic Building RenovationBy David C. Kraft
Atlas Systems, Inc. (ASI) resistance type piers were used to underpin a 100 year old historic structure at Fort Monroe, Virginia. This 3-story structure with basement was underpinned with 155 steel tu
Jan 1, 2002
-
Measuring The Soil-Structure Interaction Of Laterally Loaded PilesBy Muhannad T. Suleiman
The design of deep foundations supporting heavy buildings, bridges, transmission lines, and highway structures, is governed by lateral loads in many cases. However, due to the use of empirical or semi
Jan 1, 2011
-
Observational And Numerical Evaluation Of Defects In Deep Mixing Method Columns Used For Lng Process Train Structural Foundation SupportBy Paul J. Sabatini
Between 2008 and 2009, more than 6,000, 23-m long deep mixing method (DMM) elements were constructed to support 124 concrete mats comprising the foundations for the process trains for an LNG facility.
-
Evaluation Of Degree Of Overconservatism In Api Shaft Friction Of Piles In Marine Sand Of The Arabian GulfBy Ahmed H. Bukhary, Naser A. Al-Shayea
The objective is to assess the overconservatism in the parameters used for designing offshore piles. Methodology includes analysis of shaft friction data obtained from more than five different locatio
-
Unique Anchor Pile SOE SystemBy Andrew Stauble
This project included the replacement of the Long Island Railroad (LIRR) Atlantic 6 Bridge in New York City, which services rail traffic and spans the Van Wyck Expressway and frontage roads. The bridg
Aug 1, 2023
-
Heating and Cooling Structures with Steel Pile Foundations - Closed Loop Standing Column Well Technology (df25801f-7df6-457c-ab18-569c2a6ce07f)By Paul Suver
"The closed loop standing column well (CLSCW) system uses a closed circuit of water to develop the same thermal heat exchange characteristics that are achieved from traditional open circuit standing c
Jan 1, 2017
-
Pile Foundations For Algiers New Airport TerminalBy Ramdane Bahar
The new Algiers airport building is a reinforced concrete building of more than 80 thousand square meters of floor slabs. It is located at Dar-EI-Beida, near the old passenger terminal, about 20 km ea
Jan 1, 2002
-
Dynamic Lateral Response Of A Full-Scale Pile GroupBy Kyle M. Rollins
To improve our understanding of lateral resistance of pile groups, a series of lateral load tests were performed on a full-scale pile group using both static and dynamic loads. The pile group consiste
Jan 1, 2002
-
A Terminal UpgradeBy W. Morgan NeSmith
The city of Kansas City, Missouri, is replacing its original airport, con- structed in 1972 as a "drive-to-the- gate" facility, with a modern, single- terminal facility with just over 1 million sq ft
Oct 1, 2022
-
TECHNICAL NOTE: Direct Solution of the Brinch-Hansen 90% Pile Ultimate Failure LoadBy Don W. Dotson
In 1962, Kondner prepared several papers dealing with hyperbolic stress-strain response of cohesive soils. The following year, Brinch Hansen proposed 80% and 90% failure criteria for stress-strain be
Aug 1, 2013
-
Design and Construction of Nysted Offshore Wind Farm, DenmarkBy Jørn Thomsen, Christoffer Brodbaek
"As governments increasingly accord high priority to sustainable energy, policymakers are finding that wind energy has a long track record as a proven alternative to conventional energy supply.Over th
Jan 1, 2009
-
Use Of Geospatial Project Information Management Systems On Diaphragm And Secant Pile WallsBy Andrew Higgins, Jamey Rosen
This presentation will demonstrate some recent advancements in the applications of Project Information Systems (PIMS) technology to seepage barrier walls in the context of evolving Owner Specification
May 1, 2022
-
Session 31 "Grout Mixtures and Materials 2"By Lois G. Schwarz
I did not make studies about this parameter but I can say that some researchers recommend using low C3A cements to repair masonry mortar in order to reduce a possible combination with sulphate that ca
Feb 10, 2003