Search Documents
Search Again
Search Again
Refine Search
Refine Search
- Relevance
- Most Recent
- Alphabetically
Sort by
- Relevance
- Most Recent
- Alphabetically
-
Microstructure of Bio-Cemented Coarse Sand
By Abdelmalek Bouazza, Aamir Mahawish, Will P. Gates
Bio-grouting by means of microbial induced calcite (calcium carbonate) precipitation (MICP) to improve mechanical properties of granular soils has gained much attention in recent years. The biogroutin
Jan 1, 1900
-
A Review of the Design Formulations for Static Axial Response of Deep Foundations from Cone Penetration Test Data
By Fawad S. Niazi
Analysis of deep foundations in terms of axial capacity has been a topic of great interest in the soil-structure interaction problems. Soil behavior is governed by a series of complex stress-strain ch
Jan 1, 2013
-
Pile Driving Hammers In Centrifuge Modelling - Synopsis
By Daniel Levacher
Pile load tests in site require extensive means of action and time. To get outstanding tests, the environmental test conditions must be perfectly known and acceptable. They concern the support install
Jan 1, 1996
-
Secant Pile Top-Down Construction for a Drainage Channel in Puerto Rico: An OPA Finalist
By Bill Shea, Gordon King
"For a drainage channel built in San Juan, Puerto Rico, a value engineering (VE) proposal incorporating a secant pile top-down approach saved time and facilitated construction work on the larger flood
Jan 1, 2012
-
A Terminal Upgrade
By W. Morgan NeSmith
The city of Kansas City, Missouri, is replacing its original airport, con- structed in 1972 as a "drive-to-the- gate" facility, with a modern, single- terminal facility with just over 1 million sq ft
Oct 1, 2022
-
Testing Foundations for Major Minnesota Bridges
By Dan A. Brown, Rich A. Lamb, Paul J. Axtell
"Over the last 10 years, the Minnesota Department of Transportation (Mn/DOT) has had a very active program of replacing many major bridges, large structures spanning the Mississippi River. The deep fo
Jan 1, 2013
-
Evaluation Of Existing P-Y Models For Caliche Based On Numerical Analysis Of Raiders Stadium Lateral Load Tests
By Ramin Motamed, Fahim M. Bhuiyan, Raj V. Siddharthan
Numerical lateral load analysis based on the beam on Winkler foundation (BNWF) model (i.e., the p-y method) is a simple, and widely used tool to predict lateral responses of drilled shafts from field
Oct 1, 2022
-
Pile Settlement Design Using Continuous Surface Wave Testing And Modulus Degradation
By Hennie F. T. Barnard
Where geotechnical designs are governed by settlement requirements, soil and rock moduli are important parameters for design. This paper reports on a method that was used to utilize dynamic modulus me
-
Pile Settlement Design Using Continuous Surface Wave Testing and Modulus Degradation (9593f752-8bd1-4766-938c-27b4baad33f2)
By Hennie F. T. Barnard, Theodore E. B. Vorster
Where geotechnical designs are governed by settlement requirements, soil and rock moduli are important parameters for design. This paper reports on a method that was used to utilize dynamic modulus me
Jan 1, 2017
-
Novel Methods Of Restraining Embedded Retaining Walls
By Abid Adekunte
Traditionally, designers and contractors provide additional external supports to retaining walls through the use of tie-back anchors or braces. Both approaches are known to have their shortcomings; br
Jan 1, 2010
-
Micro-Pile Foundations in Difficult Subsurface Conditions
By D. Dreher Whetstone, Paul M. Blakita, Christopher M. Reith, Ravi P. Malviya
"Micro-piles are small diameter (5 to 10 inches), cast-in-place piles which can develop high load capacities by bonding with soil or rock. Micro-piles are particularly well-suited for moderate to heav
Jan 1, 2005
-
Vibrations Caused by Pile Driving
By K. Rainer Massarsch
"Part 2 of 2 (Continued from Summer 2004 edition) By K. Rainer Massarsch, Geo Engineering AB, Stockholm, SwedenVibrations, which are caused by the installation of piles in dry or permeable soils, can
Jan 1, 2004
-
Top-Down Methods Utilizing Secant Walls at 110 N. Carpenter: Design And Construction
By David R. Sutfin, Joseph Lodde
110 N. Carpenter is new commercial building located in the West Loop neighborhood of Chicago, Illinois. The new home to the McDonalds Corporation work headquarters, accelerated project delivery method
Jan 1, 2019
-
Collaborative Development of Sustainable & Economical Solutions for Underground Structures
By Abid Adekunte
"Whilst safety is considered to be of high priority in every aspect of engineering projects, it is equally important for designers and contractors to be continually aware of their obligations to the i
Jan 1, 2017
-
Critique of Specifications for Deep Mixing
By George Filz, Peter R. Cali
"Unnecessarily restrictive specifications could be limiting the cost effectiveness of deep mixing (DM) applications and therefore limiting use of DM on projects where there are other options. Excessiv
Jan 1, 2015
-
Army Corps Megaprojects: The Benefits of Innovative Foundations
By Dale Berner, Michael O’Sullivan
"This article focuses on lessons learned from innovative designs including in-the-wet construction methodology and modified foundation conditions, for two United States Army Corps of Engineers (USACE)
Jan 1, 2016
-
Soil-Structure Interaction Of A High-Rise Building Near Sensitive Structures In Soft Soil Conditions
By Mohamed Hassan, Matthias Seip, Steffen Leppla
In the east of Frankfurt am Main, Germany, a new high-rise building is planned directly next to the river Main. The high-rise building will have a height of about 75 m and will be founded on a Combine
May 1, 2022
-
Recent Advantages of CDM-LODIC Method (Low Displacement and Control Method)
By Yuji Yamashita, Kazuyoshi Kamimura, Tsuyoshi Takahashi, Naoya Matayoshi
"The CDM-LODIC method (cement deep mixing - low displacement and control) method enables ground displacement to be reduced by removing an amount of soil equivalent to that of injected cement slurry an
Jan 1, 2015
-
Numerical Analysis Of Mono And Group Suction Piles Under Lateral Loadings In Layered Deposits
By Juhyung Lee
Numerical analyses were performed to analyze the behavior of two different type of suction piles (mono type and group type) under various soil layer conditions (uniform silty clay layer, uniform silty
-
Cased Auger Piles (CAP): An Effective Piling Solution
By Federico Pagliacci
Continuous Flight Auger (CFA) technique represents an important technological advance in the construction of piles in soft soils. The possibility of excavation under the water table with no need for