Analysis of Alternatives for Using Cable Bolts as Primary Support at Two Low–seam Coal MinesBy Gabriel S. Esterhuizen
"Cable bolts are sometimes used in low-seam coal mines to provide support in difficult ground conditions. This paper describes cable bolting solutions at two low-seam coal mines in similar ground cond
Jan 1, 2015
-
Mapping Hazards With Microseismic Technology To Anticipate Roof Falls - A Case Study (ac4523c6-7bdb-4660-a1cb-20433a65c0ed)By Anthony Iannacchione
As the amount of new fractured surfaces or "damaged rock layers" within roof rock increases, the stability of the rock mass decreases. While direct measurements of this phenomenon are not easily made,
Jan 1, 2004
-
Stone Mine Design in Highly Fractured Rock (af82e9d2-530a-42f2-9d22-f8c466af0da2)By Vincent Scovazzo
Cost-effective underground mine configurations have been designed in highly fractured rock masses where the stone possesses a high material strength. A limestone mine in the eastern United States is u
Jan 1, 2002
-
Management of the Dynamic Phenomena of Rock Pressure in Underground MinesBy Vladimir I. Klishin
Complex method of ruling of rock pressure is considered in conditions of rapid roof subsidence. The purpose of this method is elaboration of emergency devices into hydraulic props. Also method of unlo
Jan 1, 1997
-
Anchorage Pull Testing for Fully Grouted Roof BoltsBy Chris Mark
Fully-grouted roof bolts comprise more than 80% of the primary roof supports used in U.S. coal mines. However, nearly 1,500 MSHA reportable, non-injury roof falls occur each year, and most of these ar
Jan 1, 2002
-
A Novel and Effective Method to Develop Tension in a Roof BoltBy Phillip E. Gramlich
Through extensive practical experience and multiple studies, tensioned roof control systems have proven beneficial in difficult mining conditions. Due to increased mining of less desirable seams, ten
Jan 1, 2014
-
Longwall Mining Of Thin SeamsBy Ernest A. Curth
An estimated 49 billion tons or 29 percent, of the coal reserve base to a depth of 1,000 feet in the eastern United States fall in the 28- to 42-inch range. Often left out as a consequence of selectiv
Jan 1, 1981
-
International Experience with Longwall Mining into Pre-driven Rooms (7f55d3bb-2127-4b96-860d-e3684bbd8397)By David Oyler
Unusual circumstances may require that a longwall retreat into or through a previously driven room. The operation can be completed successfully, but there have been a number of spectacular failures wh
Jan 1, 1998
-
Analysis Of Roof Bolt Systems (80829435-dd55-4b61-96dd-df38d097e9ff)By Christopher Mark
Despite more than half a century of experience with roof bolting, no design method has received wide acceptance. To begin to improve this situation, National Institute for Occupational Safety and Heal
Jan 1, 2001
-
Manifestation Of Mine Pressure And Its Relations To Overlying Strata MovementsBy Z. C. Song
[THIS PAPER WAS TRANSLATED FROM CHINESE TO ENGLISH BY S. S. PENG, WEST VIRGINIA UNIVERSITY] Immediately after coal extraction, the pressure that causes the movement of the surrounding strata is c
Jan 1, 1982
-
Application of Tensioned Cable Bolts for Supplemental SupportBy Ben Mirabile, Alan Campoli, Rodney Poland
"The majority of U.S. underground coal mines use some form of cable bolt as supplemental support to a primary roof bolting system. Many coal operators employ the high load capacity of non-tensioned ca
Jan 1, 2010
-
Assessment of Rockburst Hazard by Quantifying the Consequence with Plastic Strain Work and Released Energy in Numerical ModelsBy R. Kaund
"Quantifying the rockburst consequence is of critical importance to reduce the hazards with preventative measures in underground mines and deep tunnels. Contours of energy components within a pillar m
Jan 1, 2018
-
Multi?Seam Mining Over Old Workings with Small Pillars - A Case StudyBy Peter Zhang
Room and pillar mining under shallow depth is usually conducted with a high extraction ratio, which leaves small pillars with a low safety factor in some old workings in abandoned mines. Pillar slough
Jan 1, 2014
-
Considerations Of Gas Outbursts In Using Dome Salt Mines For Storage Of Oil And Nuclear WasteBy M. Ashraf Mahtab
A feature of interest in stability of excavations in domal salt is the phenomenon of gas outbursts which has occurred in five of the six mines in Louisiana salt domes. Gas outbursts are sudden errupti
Jan 1, 1981
-
Thrust Bolting: A New Innovation In Coal Mine Roof SupportBy Stephen C. Tadolini
A new innovation in coal mine roof support has been developed by the Bureau of Mines at the Denver Research Center. The technique, called "Thrust Bolting,"1 converts a traditional passive roof support
Jan 1, 1990
-
A Rock Mass Strength Concept For Coal SeamsBy George S. Kalamaras
Coal strata strength is included as a vague term in most of the pillar design formulas, either as a questionable fraction of the intact coal strength or a size-dependent relationship for scaling down
Jan 1, 1993
-
Monitoring For The Evaluation Of The Stability Of Underground OpeningsBy P. K. Kaiser
The purpose of deformation monitoring for the evaluation of the stability of underground openings is reviewed briefly and some results from laboratory tests of small tunnels are presented. The ground
Jan 1, 1981
-
In Situ Stress For Underground Excavation Design In A Naturally Fractured Rock MassBy Andrew J. Hyett
The ISRM commission on testing methods has recently presented Suggested Methods for rock stress determination (Kim & Franklin, 1987). This proposes that even if the magnitude of in situ stress is not
Jan 1, 1989
-
Evaluation Of Surface Subsidence Potential Along A Pipeline Due To Abandoned Coal Mine WorksBy Thomas L. Vandergrift
With the inevitable expansion of homes, businesses, and infrastructure in coal mining regions, the potential for future subsidence above abandoned mines is of increasing concern. Of particular concern
Jan 1, 2000
-
A Model Of Shield-Strata Interaction And Its Implications For Active Shield Setting RequirementsBy Thomas M. Baraak
This paper evaluates factors which influence longwall support and strata interaction. The longwall system is composed of an immediate and main roof structure and three supporting foundations: 1) longw