The Introduction of Uk Rockbolting Technology into Coal MinesAround the WorldBy Graham Daws
The introduction of UK rock bolting technology has been applied in many large underground coal mines around the world. This paper explains the methods that have been applied for its successful introdu
Jan 1, 2011
-
A New Rock Bolting Concept For Underground RoadwaysBy G. Skybey
The Skybolt is a new bolt concept, point anchored with resin in large diameter holes of specific sizes 38 mm and 45 mm. The new design achieves the optimum annular spacing required for mixing the resi
Jan 1, 1992
-
Tensioned Cable Bolts As Primary Support: UpdateBy John C. Stankus
At the 19th International Conference on Ground Control in Mining, a paper was presented detailing new types of Jennmar INSTáL tensionable cable bolts (Stankus and Taylor, 2000). Since that time, signi
Jan 1, 2001
-
A Methodology for Fault Pre-Consolidation prior to Longwall Retreat: A Case Study from Kestrel CoalBy Dion Pastars
Kestrel Coal has undertaken a surface-to-seam consolidation program of faulted ground prior to longwall retreat in the 304 panel. Micro fine cement is used to improve the rock mass quality and the
Jan 1, 2007
-
Geotechnical Constraints On A 6 M Single Pass LongwallBy Ross W. Seedsman
The feasibility of 6 m high single pass longwalling has been studied using Newlands Mine as a case study An intensive geological investigation identified a range of hazards but a mine layout was possi
Jan 1, 1992
-
Problems in "Void" Detection in Coal Mine Water HazardsBy Francis Kendorski
One of the most dangerous events in underground coal mining is unexpectedly encountering water inrushes from undetected abandoned mines in the same seam. The surest and most confident method is probe
Jan 1, 2004
-
The Directional Drill Monitor For Long Hole Gas Drainage In Coal Mines (d6b87c76-5ad8-4cc5-b4ae-23b79c52c32b)By G. Skybey
The Directional Drill Monitor (DDM) is an advanced instrument for real time in hole surveying. It was developed by Du Pont (Australia) to suit Australian gassy coal mining conditions. The instrumen
Jan 1, 1992
-
A New Rock Mass Failure Criteria Based On Rate Of MovementBy Hamid Maleki
A new failure criteria is proposed for assessment of roof stability in underground sedimentary rocks. Unlike other stability assessment techniques, this method is simple and practical, having improved
Jan 1, 1990
-
Roof Control With Polyurethane For Recovery Of Kitt Energy?s 1000-Foot LongwallBy J. G. Stewart
Polyurethane injection for the consolidation and control of broken strata is a common practice in the deep mines in Europe. The technology has gained wide acceptance in the coal mines of America since
Jan 1, 1984
-
Analysis Of The Seam Inclination Effect On Roof StabilityBy Hanjie Chen
Mining experiences have shown that in a pitching seam, roof behavior is significantly different from a flat seam. Uphill mining usually experiences more roof problems than downhill mining. Based on a
Jan 1, 2000
-
Investigation Of Subsidence Event Over Multiple Seam Mining Area (b421bdde-19e7-491b-bc6d-a4cce9ef42b4)By Kewal K. Kohli
An investigation was performed to determine the sequence of events which caused the 1987 surface subsidence and related damage to several homes in Walker County, Alabama, USA (see Figure 1). Surface a
Jan 1, 1992
-
Comparison Of Multiple And Single Entry Roadways For Highly Stressed LongwallsBy Klaus Opolony
The world's most popular method of longwall mining requires multiple entry systems for the panels. In contrast to this mine layout the roadways in German coal mining are used for advanced mining
Jan 1, 2003
-
Salt Pillar Design EquationBy Leo L. Van Sambeek
Specification of properly sized pillars to support the overburden is one of the most challenging aspects of salt mine design. Interest in salt pillar design is heightened by the recent flooding of th
Jan 1, 1997
-
Tension-Torque Relationship For Mechanical Anchored Roof BoltsBy H. N. Maleki
Tension-torque relationships were investigated *n a coal mine for bath standard 5/8 in. (16 mm) bolts and a vibrating wire instrumented bolt, using conventional and controlled installation techniques.
Jan 1, 1984
-
Influences of Longwall Subsidence on a Guyed Steel Tower - A Case StudyBy Yi Luo
The potential influences of mining subsidence on structural stability, integrity and functionality of guyed tower structures have not been systematically studied before. This paper presents a ease stu
Jan 1, 2003
-
Pressure Measurements in the Gob (27227c3c-951c-4108-ba5c-3b6e67d232fb)By H. Maleki
Gob pressure measurements were made in a Western U. S. coal mine as part of a long-term program to evaluate cave progress and to determine the influence of geological discontinuities on caving conditi
Jan 1, 1984
-
Numerical Simulation on Microseismicity Due to Mining at One of the Collieries in AustraliaNumerical simulation for microseismicity due to mining at one of the collieries in Australia was carried out and the results were compared to the observed microscismicity. 3-D Stress analysis showe
Jan 1, 2001
-
Current Trends In Roof Truss HardwareBy C. P. Mangelsdorf
The success of the Birmingham roof truss (Figure 1) in supporting some difficult roof conditions, particularly in the Illinois coal basin, has given impetus to the development of a number of alternate
Jan 1, 1982
-
Analysis of Alternatives for Using Cable Bolts as Primary Support at Two Low–seam Coal MinesBy Gabriel S. Esterhuizen
"Cable bolts are sometimes used in low-seam coal mines to provide support in difficult ground conditions. This paper describes cable bolting solutions at two low-seam coal mines in similar ground cond
Jan 1, 2015
-
Mechanical Properties of Pizza Pans and Their Effectiveness in Underground Coal MiningBy Brian Daniels, James Farroni
"Draw rock (small rock that forms/falls when bolting the roof and/or rib) is the cause of numerous injuries annually. These injuries result in lost work hours and low morale. The report below explains
Jan 1, 2010