  • DFI
    Pile Driving Hammers In Centrifuge Modelling - Synopsis

    By Daniel Levacher

    Pile load tests in site require extensive means of action and time. To get outstanding tests, the environmental test conditions must be perfectly known and acceptable. They concern the support install

    Jan 1, 1996

  • DFI
    Behavior of Settlement Reducing Piles under Static and Seismic Loadings

    By Marwa Nabil, Alaa A. Ata

    "Recent developments in the analysis of piled rafts has incorporated the load sharing of the raft and the piles to support the superstructure. In the piled-raft system, piles are cast monolithically w

    Jan 1, 2016

  • DFI
    Dynamic Load Testing of 2 Metre Steel Tubular Piles Driven into Foliated Phyllite Bedrock

    By Bosco Poon, Kim Chan, Luis Raúl Castañeda, Geoff McKay

    "Driven steel tubular piles of up to 2 m diameter have been used to support abutments and piers of a bridge over Nambucca River and floodplain. The bridge was designed by Arup-Aurecon Design Joint Ven

    Jan 1, 1900

  • DFI
    Bedrock Evaluation For Deep Foundations Utilizing An Acoustic Televiewer, I-70 New Mississippi River Bridge, St. Louis, Missouri

    By Adrian M. Keller

    Borehole televiewers are downhole inspection devices available for high-resolution imaging of a borehole wall following rock coring. Borehole televiewers should be considered by geotechnical engineer

    Jan 1, 2010

  • DFI
    Downdrag Effects on the Pile Groups Supporting Bridge Abutments

    By M. Hesham El Naggar, Tony Sangiuliano, Alper Turan

    "Bridge abutments supported on pile foundations are often constructed over weak and compressible soils. The consolidation settlements induced by the embankment loads are known to result in downdrag an

    Jan 1, 2015

  • DFI
    Brightman Street Bridge Replacement Project (fbb13111-569c-48aa-97e7-9bb48f6ec170)

    By Jeffrey M. Taylor, Arturo Ressi di Cervia

    "Construction of the drilled shafts for the Brightman Street Bridge Replacement Project were not only challenging due to working over the water but were also challenged by changed soil conditions, con

    Jan 1, 2004

  • DFI
    Session 23 "Grout in Rock and Mining"

    By John Davie

    We used a Remtek survey in Glenrock and had very good luck with it when we first started the initial investigation. We would have loved to have used that more but my understanding is the equipment is

    Feb 10, 2003

  • DFI
    Behaviour Of Piled Raft- Importance Of Observational Study

    By Abhirami B., V. Balakumar

    Piled raft foundation system is an intelligent geotechnical concept, developed towards reducing the settlement of the raft and the footings by providing pile elements below the raft or footings, as th

    Nov 1, 2022

  • DFI
    Deep Cement Mixing (DCM) Quality Assessment Using Real-Time Operational Parameters Data

    By Soon-Hoe Chew

    Deep Cement Mixing (DCM) is a well-established ground improvement technique renowned for its efficacy. It has been widely adopted due to its robustness and effectiveness in stabilizing weak or soft so

    Oct 7, 2024

  • DFI
    Field Sampling and Testing for Soil Mixing – Uses and Misuses of Different QA/QC Tests for CDSM Projects – A Contractor’s Perspective

    By A. David Miller, Chika Oya

    "Field sampling and testing are part of the Quality Assurance/Quality Control (QA/QC) requirements for all Cement Deep Soil Mixing (CDSM) Projects. Field sampling and testing are also used for determi

    Jan 1, 2017

  • DFI
    A Non-Destructive Monitoring System for QA/QC of Cement-Bentonite Cut-off Walls

    By Sathya Subramanian, Jun Yuan Ryan Lee, Angelina Yi Tian Theng, Kai En Low, Soon-Hoe Chew, Yeow Chong Tan, Kai Yang Toh, Pei Ling Goh

    Conventional Quality Assurance and Quality Control (QA/QC) methods for Cement Bentonite (CB) walls rely on destructive coring, which is carried out at specific curing times like 28 days or 91 days. Th

    Oct 7, 2024

  • DFI
    Full Scale Load Test Program Confirms the Design of a Rigid Inclusions Solution for the Support of an MSE Wall in Southern New Jersey

    By Susan Rafalko, Mike Walker, John Sankey, Sherif Aziz, Alex Potter-Weight, Mary Nodine, Frederic Masse

    "After several successful projects on the Garden State Parkway and New Jersey Turnpike for support of single-stage MSE (Mechanically Stabilized Earth) walls using rigid inclusions (Controlled Modulus

    Jan 1, 2015

  • DFI
    Long Term Performance of Grouts and the Effects of Grout By-Products

    By Stephan A. Jefferis

    I presume that the questioner is not asking about the reduction of sulfate in groundwater to hydrogen sulfide as a result of biological activity promoted by organics in the grout hardener and that the

    Feb 10, 2003

  • DFI
    Design And Field Comparison Of Ground Improvement And Bored Piles For Large Diameter Steel Water Tanks

    By Vijaya Bhushan Rao, Ali Semercioglu, Jason Redgers

    Large diameter steel water tanks with high storage capacities impart heavy loads deep into the ground, generally requiring deep foundations to adequately support them. The use of ground improvement as

    Oct 1, 2022

  • DFI
    Applications of Diaphragm Wall Technology for Deep Foundations and Permanent Underground Structures for the Transbay Transit Center and the Transbay Developments

    By Mikael Calando, Thomas Joussellin

    "San Francisco's rapid growth has caused the city to plan for the Transbay Transit Center Project, a visionary transportation and housing project, that will transform downtown San Francisco and the Sa

    Jan 1, 2016

  • DFI
    Real-Time Monitoring During Shaft Contruction For The Sound Transit Ulink I-5 Undercrossing

    By Pierre Gouvin

    This paper describes the design, installation and monitoring of a state of the art real time geotechnical/structural instrumentation monitoring system to facilitate tunnel construction under Interstat

    Jan 1, 2010

  • DFI
    Rapid Load Testing In Germany

    By Marcel Bielefeld, Joost Bakker, Rob van Dorp

    Pile load testing can be performed by a static, rapid or high strain dynamic (generally designated as dynamic) testing method. The static load test is often considered the “gold standard” of testing w

    May 1, 2022

  • DFI
    The Construction And Performance Of Post-Grouted Micro-Piles For Vancouver International Airport Domestic Terminal Building - Introduction

    By Ernest Naesgaard

    Post-grouted micro-piles were used for the seismic upgrading of the Vancouver International Airport Domestic Terminal Building (DTB). The micro-piles provided vertical resistance to both uplift and c

    Jan 1, 2004

  • DFI
    Observational and Numerical Evaluation of Defects in Deep Mixing Method Columns Used for LNG Process Train Structural Foundation Support (30cbb62b-9335-4a4e-8105-e672f3e82ba5)

    By Paul Summers, Kevin Richardson, Willem (Billy) Villet, Paul J. Sabatini, Edward C. Clukey

    "Between 2008 and 2009, more than 6,000, 23-m long deep mixing method (DMM) elements were constructed to support 124 concrete mats comprising the foundations for the process trains for an LNG facility

    Jan 1, 2017

  • DFI
    A Study On The Evaluation Of Pile Bearing Capacity Factor And Adhesion Factor In Is 2911

    By Ashirbad Satapathy, Sanket Rawat, Ramanand Shukla, Ravi Kant Mittal

    Bearing capacity factor (Nq) and Adhesion factor (α) are the key parameters for analyzing the load carrying capacity of pile foundations embedded in cohesionless and cohesive soils respectively. Numer

    Nov 1, 2022