Open Circuit Disc Balling At Hamersley's Dampieer Pelletizing Plant
    
    - Organization:
 - The Australasian Institute of Mining and Metallurgy
 - Pages:
 - 8
 - File Size:
 - 437 KB
 - Publication Date:
 - Jan 1, 1974
 
Abstract
The considerations which led to the decision to_ install discs at the Dampier  Pellet Plant of Hamer ley Iron Pty. Ltd.  are described. Initial testwork showed  that the ore could be ground dry in open  circuit to a Blaine index of 2500 cm2/g  and that it pelletized readily. The  various design criteria including  diameter, slope, speed, motor size,  depth of sidewall, feed point and water  spray location were then determined.  Plant performance after commissioning is  described including the various problems  encountered and the modifications since  carried out to overcome them. The main  problem was quickly identified as disc  feed rate control. Various bin and bin  feeder modifications were tried to  overcome the effects of the fluidising  characteristics of the dry ground ore.  Other factors found to affect disc  operation are ore size distribution,  additives and operator competence.
Citation
APA: (1974) Open Circuit Disc Balling At Hamersley's Dampieer Pelletizing Plant
MLA: Open Circuit Disc Balling At Hamersley's Dampieer Pelletizing Plant. The Australasian Institute of Mining and Metallurgy, 1974.